Generator Basics

ENERGY
GENERATOR = GUARANTEED POWER: When sun isn't shining and batteries are low, a generator delivers. But it burns fuel, makes noise, and needs maintenance.
Goal: Right-sized backup that runs when needed, sips fuel, and lasts for years.

Generator Types

Gasoline

Gasoline degrades. Add stabilizer when storing. Rotate fuel supply annually.

Propane

Propane never goes bad. Best fuel for long-term backup. Large tank = weeks of runtime.

Diesel

Diesel engines last longest (10,000+ hours). Best for frequent use. Fuel stores 1-2 years with treatment.

Dual/Tri-Fuel

Best of all worlds. Run on propane for storage, switch to gas if propane runs out. Conversion kits available for many generators.

Inverter Generators

Honda EU series is the gold standard. Predator, Champion, Westinghouse offer good value alternatives.

Quick Comparison

TypeCostFuel LifeRuntime/TankBest For
GasolineLow6-12 mo8-12 hrsOccasional use, budget
PropaneMediumForeverVariesLong-term backup
DieselHigh1-2 yrs12-24 hrsFrequent/heavy use
Dual-fuelMediumPropane storeVariesFlexibility
InverterHighGas/propane8-20 hrsElectronics, quiet

Sizing Your Generator

Calculate Running Load

Add up watts of everything you want to run simultaneously:

Running watts = Sum of all devices you'll use at once

Account for Surge

Some devices need 2-3x their running watts to start:

Surge capacity needed = Highest surge in your list

Generators have two ratings: Running watts (continuous) and Starting watts (surge for seconds). Size for running, verify surge covers your biggest startup.

Sizing Examples

Essentials only (2000W): Fridge, lights, phone chargers, furnace fan. Portable inverter works.

Comfort backup (5000W): Above + freezer, microwave, TV, window AC in one room.

Whole house (10,000W+): Everything including well pump, electric water heater, multiple AC units.

Run Schedule

For Battery Charging

When solar can't keep up, run generator to charge batteries efficiently:

Generator is most efficient at 50-75% load. Running at 10% load wastes fuel. Run hard, then shut off.

For Direct Power

During extended outages, run generator in blocks:

6 hours of runtime per day can keep essentials going for weeks on modest fuel supply.

Fuel Storage & Rotation

Gasoline

NEVER store gasoline inside living space. Garage with ventilation or shed. Keep away from ignition sources.

Propane

Five 20lb tanks = roughly 15-25 hours of runtime for 3000W generator. Scale to your needs.

Diesel

Diesel farms often have 100+ gallons on hand. Add biocide when storing, test periodically.

Exhaust Safety

CARBON MONOXIDE KILLS: Generator exhaust contains CO. You cannot see or smell it. Running a generator indoors or near open windows can be fatal in minutes.
ALWAYS: Run generators outdoors, at least 20 feet from any building opening. Point exhaust away from structures.

Safe Placement

Maintenance

Before Each Use

Monthly (When Stored)

"Exercise" your generator monthly. Generators that sit for months often won't start when needed.

Annual Service

DIY: Most generator maintenance is simple. Oil change, spark plug, air filter. Keep spare parts on hand.

Common Mistakes

Transfer Switch Basics

Why You Need One

To power your house panel from a generator, you need a transfer switch. It prevents backfeeding the grid (killing lineworkers) and isolates generator power from utility power.

Backfeeding (generator into wall outlet) is illegal and dangerous. It energizes the grid side of your panel and can kill utility workers repairing lines.

Checklists

Before Outage Season

Before Starting

During Extended Run

Scenario Drills

Generator won't start

  1. Check fuel level and fuel valve
  2. Check oil level (low oil shutoff)
  3. Try fresh fuel if gas is old
  4. Check spark plug connection
  5. Check choke position
  6. Pull cord slowly until resistance, then pull firmly
  7. If electric start, check battery

Generator runs but no power

  1. Check circuit breaker on generator
  2. Verify outlets aren't GFI tripped
  3. Check extension cord connections
  4. Test with different load (light bulb)
  5. If inverter type, may need reset - check manual

Generator surging or hunting

  1. Likely fuel issue - check for water or debris in fuel
  2. Try fresh fuel
  3. Check air filter (clogged filter = rich mixture)
  4. Carburetor may need cleaning (old fuel varnish)